Advanced Control¶
Note
The below features are designed for advanced users who wish to use the Opentrons API in their own Python environment (ie Jupyter). This page is not relevant for users only using the Opentrons App, because the features described below will not be accessible.
The robot module can be thought of as the parent for all aspects of the Opentrons API. All containers, instruments, and protocol commands are added to and controlled by robot.
'''
Examples in this section require the following
'''
from opentrons import robot, containers, instruments
plate = containers.load('96-flat', 'B1', 'my-plate')
tiprack = containers.load('tiprack-200ul', 'A1', 'my-rack')
pipette = instruments.Pipette(axis='b', max_volume=200, name='my-pipette')
Head Speed¶
The maximum speed of the robot’s head can be set using
robot.head_speed(). The value we set the speed to is in millimeters-per-second
(mm/sec).
robot.head_speed(5000)
Note
Setting the head speed to above
6000
mm/sec
may cause your robot to “skip”, which means the
motors will lose their grip and make a loud vibrating noise.
We recommend you try out different speed values on your
robot, and see what works and what doesn’t.
Homing¶
You can home the robot by calling
home(). You can also specify axes. The robot will home immdediately
when this call is made.
robot.home() # home the robot on all axis
robot.home('z') # home the Z axis only
Commands¶
When commands are called on a pipette, they are recorded on
the
robot
in the order they are called. You can see all past executed
commands by calling
robot.commands(), which returns a
Python list.
pipette.pick_up_tip(tiprack.wells('A1'))
pipette.drop_tip(tiprack.wells('A1'))
for c in robot.commands():
print(c)
will print out...
Picking up tip from <Deck><Slot A1><Container my-rack><Well A1>
Drop_tip at <Deck><Slot A1><Container my-rack><Well A1>
Clear Commands¶
We can erase the robot command history by calling
robot.clear_commands(). Any previously created instruments and containers will
still be inside robot, but the commands history is erased.
robot.clear_commands()
pipette.pick_up_tip(tiprack['A1'])
print('There is', len(robot.commands()), 'command')
robot.clear_commands()
print('There are now', len(robot.commands()), 'commands')
will print out...
There is 1 command
There are now 0 commands
Comment¶
You can add a custom message to the list of command
descriptions you see when running
robot.commands(). This command is
robot.comment(), and it allows you to print out any information you want at
the point in your protocol
robot.clear_commands()
pipette.pick_up_tip(tiprack['A1'])
robot.comment("Hello, just picked up tip A1")
pipette.pick_up_tip(tiprack['A1'])
robot.comment("Goodbye, just dropped tip A1")
for c in robot.commands():
print(c)
will print out...
Picking up tip from <Deck><Slot A1><Container my-rack><Well A1>
Hello, just picked up tip A1
Picking up tip from <Deck><Slot A1><Container my-rack><Well A1>
Goodbye, just dropped tip A1
Get Containers¶
When containers are loaded, they are automatically added to
the
robot. You can see all currently held containers by calling
robot.get_containers(), which returns a
Python list.
for name, container in robot.get_containers():
print(name, container.get_type())
will print out...
my-plate 96-flat
my-rack tiprack-200ul
Get Instruments¶
When instruments are created, they are automatically added to
the
robot. You can see all currently held instruments by calling
robot.get_instruments(), which returns a
Python list.
for axis, pipette in robot.get_instruments():
print(pipette.name, axis)
will print out...
my-pipette B
Reset¶
Calling
robot.reset()
will remove everything from the robot. Any previously added
containers, pipettes, or commands will be erased.
robot.reset()
print(robot.get_containers())
print(robot.get_instruments())
print(robot.commands())
will print out...
[]
[]
[]