API Reference¶
If you are reading this, you are probably looking for an in-depth explanation of API classes and methods to fully master your protocol development skills.
Robot¶
All protocols are set up, simulated and executed using a Robot class.
-
class
opentrons.Robot¶ This class is the main interface to the robot.
- Through this class you can can:
Each Opentrons protocol is a Python script. When evaluated the script creates an execution plan which is stored as a list of commands in Robot’s command queue.
- Here are the typical steps of writing the protocol:
- Using a Python script and the Opentrons API load your
containers and define instruments
(see
Pipette). - Call
reset()to reset the robot’s state and clear commands. - Write your instructions which will get converted into an execution plan.
- Review the list of commands generated by a protocol
commands(). connect()to the robot and callrun()it on a real robot.
- Using a Python script and the Opentrons API load your
containers and define instruments
(see
See
Pipettefor the list of supported instructions.Examples
>>> from opentrons import robot, instruments, containers >>> robot.reset() <opentrons.robot.robot.Robot object at ...> >>> plate = containers.load('96-flat', 'A1', 'plate') >>> p200 = instruments.Pipette(axis='b', max_volume=200) >>> p200.aspirate(200, plate[0]) <opentrons.instruments.pipette.Pipette object at ...> >>> robot.commands() ['Aspirating 200 at <Deck><Slot A1><Container plate><Well A1>']
-
actions¶ Return a copy of a raw list of commands in the Robot’s queue.
-
add_instrument(axis, instrument)¶ Adds instrument to a robot.
Parameters: - axis (str) – Specifies which axis the instruments is attached to.
- instrument (Instrument) – An instance of a
Pipetteto attached to the axis.
Notes
A canonical way to add to add a Pipette to a robot is:
from opentrons.instruments.pipette import Pipette p200 = Pipette(axis='a')
This will create a pipette and call
add_instrument()to attach the instrument.
-
commands()¶ Access the human-readable list of commands in the robot’s queue.
Returns: - A list of string values for each command in the queue, for example
'Aspirating 200uL at <Deck>/<Slot A1>/<Container plate>/<Well A1>'
-
connect(port=None, options=None)¶ Connects the robot to a serial port.
Parameters: - port (str) – OS-specific port name or
'Virtual Smoothie' - options (dict) – if
portis set to'Virtual Smoothie', provide the list of options to be passed toget_virtual_device()
Returns: Return type: Truefor success,Falsefor failure.- port (str) – OS-specific port name or
-
containers()¶ Returns the dict with all of the containers on the deck.
-
diagnostics()¶ Access diagnostics information for the robot.
Returns: axis_homed— axis that are currently in home position.switches— end stop switches currently hit.steps_per_mm— steps per millimeter calibration
values for
xandyaxis.Return type: Dictionary with the following keys
-
disconnect()¶ Disconnects from the robot.
-
get_mosfet(mosfet_index)¶ Get MOSFET for a MagBead (URL).
Parameters: mosfet_index (int) – Number of a MOSFET on MagBead. Returns: Return type: Instance of InstrumentMosfet.
-
get_motor(axis)¶ Get robot’s head motor.
Parameters: axis ({'a', 'b'}) – Axis name. Please check stickers on robot’s gantry for the name.
-
get_warnings()¶ Get current runtime warnings.
Returns: - Runtime warnings accumulated since the last
run() - or
simulate().
- Runtime warnings accumulated since the last
-
head_speed(*args, **kwargs)¶ Set the XY axis speeds of the robot, set in millimeters per minute
Parameters: rate (int) – An integer setting the mm/minute rate of the X and Y axis. Speeds too fast (around 6000 and higher) will cause the robot to skip step, be careful when using this method Examples
>>> from opentrons import robot >>> robot.connect('Virtual Smoothie') >>> robot.home() >>> robot.head_speed(4500) >>> robot.move_head(x=200, y=200)
-
home(*args, **kwargs)¶ Home robot’s head and plunger motors.
Parameters: *args – A string with axes to home. For example
'xyz'or'ab'.If no arguments provided home Z-axis then X, Y, B, A
Notes
Sometimes while executing a long protocol, a robot might accumulate precision error and it is recommended to home it. In this scenario, add
robot.home('xyzab')into your script.Examples
>>> from opentrons import Robot >>> robot.connect('Virtual Smoothie') >>> robot.home()
-
move_to(location, instrument=None, strategy='arc', **kwargs)¶ Move an instrument to a coordinate, container or a coordinate within a container.
Parameters: - location (one of the following:) – 1.
Placeable(i.e. Container, Deck, Slot, Well) — will move to the origin of a container. 2.Vectormove to the given coordinate in Deck coordinate system. 3. (Placeable,Vector) move to a given coordinate within object’s coordinate system. - instrument – Instrument to move relative to. If
None, move relative to the center of a gantry. - strategy ({'arc', 'direct'}) –
arc: move to the point using arc trajectory avoiding obstacles.direct: move to the point in a straight line.
Examples
>>> from opentrons import Robot >>> robot.reset() <opentrons.robot.robot.Robot object at ...> >>> robot.connect('Virtual Smoothie') >>> robot.home() >>> plate = robot.add_container('96-flat', 'A1', 'plate') >>> robot.move_to(plate[0]) >>> robot.move_to(plate[0].top())
- location (one of the following:) – 1.
-
reset()¶ - Resets the state of the robot and clears:
- Deck
- Instruments
- Command queue
- Runtime warnings
-
stop()¶ Stops execution of the protocol.
Pipette¶
-
class
opentrons.instruments.Pipette(robot, axis, name=None, channels=1, min_volume=0, max_volume=None, trash_container=None, tip_racks=[], aspirate_speed=300, dispense_speed=500)¶ - Through this class you can can:
- Handle liquids with
aspirate(),dispense(),mix(), andblow_out() - Handle tips with
pick_up_tip(),drop_tip(), andreturn_tip() - Calibrate this pipette’s plunger positions
- Calibrate the position of each
Containeron deck
- Handle liquids with
- Here are the typical steps of using the Pipette:
- Instantiate a pipette with a maximum volume (uL)
and an axis (a or b) * Design your protocol through the pipette’s liquid-handling commands
Parameters: - axis (str) – The axis of the pipette’s actuator on the Opentrons robot (‘a’ or ‘b’)
- name (str) – Assigns the pipette a unique name for saving it’s calibrations
- channels (int) – The number of channels on this pipette (Default: 1)
- min_volume (int) – The smallest recommended uL volume for this pipette (Default: 0)
- max_volume (int) – The largest uL volume for this pipette (Default: min_volume + 1)
- trash_container (Container) – Sets the default location
drop_tip()will put tips (Default: None) - tip_racks (list) – A list of Containers for this Pipette to track tips when calling
pick_up_tip()(Default: []) - aspirate_speed (int) – The speed (in mm/minute) the plunger will move while aspirating (Default: 300)
- dispense_speed (int) – The speed (in mm/minute) the plunger will move while dispensing (Default: 500)
Returns: Return type: A new instance of
Pipette.Examples
>>> from opentrons import instruments, containers >>> p1000 = instruments.Pipette(axis='a', max_volume=1000) >>> tip_rack_200ul = containers.load('tiprack-200ul', 'A1') >>> p200 = instruments.Pipette( ... name='p200', ... axis='b', ... max_volume=200, ... tip_racks=[tip_rack_200ul])
-
aspirate(volume=None, location=None, rate=1.0)¶ Aspirate a volume of liquid (in microliters/uL) using this pipette
Notes
If no location is passed, the pipette will aspirate from it’s current position. If no volume is passed, aspirate will default to it’s max_volume
Parameters: - volume (int or float) – The number of microliters to aspirate (Default: self.max_volume)
- location (
Placeableor tuple(Placeable,Vector)) – ThePlaceable(Well) to perform the aspirate. Can also be a tuple with first itemPlaceable, second item relativeVector - rate (float) – Set plunger speed for this aspirate, where
speed = rate * aspirate_speed (see
set_speed())
Returns: Return type: This instance of
Pipette.Examples
>>> p200 = instruments.Pipette( ... name='p200', axis='a', max_volume=200)
>>> # aspirate 50uL from a Well >>> p200.aspirate(50, plate[0]) <opentrons.instruments.pipette.Pipette object at ...>
>>> # aspirate 50uL from the center of a well >>> p200.aspirate(50, plate[1].bottom()) <opentrons.instruments.pipette.Pipette object at ...>
>>> # aspirate 20uL in place, twice as fast >>> p200.aspirate(20, rate=2.0) <opentrons.instruments.pipette.Pipette object at ...>
>>> # aspirate the pipette's remaining volume (80uL) from a Well >>> p200.aspirate(plate[2]) <opentrons.instruments.pipette.Pipette object at ...>
-
blow_out(location=None)¶ Force any remaining liquid to dispense, by moving this pipette’s plunger to the calibrated blow_out position
Notes
If no location is passed, the pipette will blow_out from it’s current position.
Parameters: location ( Placeableor tuple(Placeable,Vector)) – ThePlaceable(Well) to perform the blow_out. Can also be a tuple with first itemPlaceable, second item relativeVectorReturns: Return type: This instance of Pipette.Examples
>>> p200 = instruments.Pipette(name='p200', axis='a', max_volume=200) >>> p200.aspirate(50).dispense().blow_out() <opentrons.instruments.pipette.Pipette object at ...>
-
calibrate(position)¶ Calibrate a saved plunger position to the robot’s current position
Notes
This will only work if the API is connected to a robot
Parameters: position (str) – Either “top”, “bottom”, “blow_out”, or “drop_tip” Returns: Return type: This instance of Pipette.Examples
>>> robot = Robot() >>> p200 = instruments.Pipette(axis='a') >>> robot.move_plunger(**{'a': 10}) >>> # save plunger 'top' to coordinate 10 >>> p200.calibrate('top') <opentrons.instruments.pipette.Pipette object at ...>
-
calibrate_position(location, current=None)¶ Save the position of a
Placeable(usually aContainer) relative to this pipette.Notes
The saved position will be persisted under this pipette’s name and axis (see
Pipette)Parameters: - location (tuple(
Placeable,Vector)) – A tuple with first itemPlaceable, second item relativeVector - current (
Vector) – The coordinate to save this container to (Default: robot current position)
Returns: Return type: This instance of
Pipette.Examples
>>> robot.reset() <opentrons.robot.robot.Robot object at ...> >>> tiprack = containers.load('tiprack-200ul', 'A1') >>> p200 = instruments.Pipette(axis='a') >>> robot.move_head(x=100, y=100, z=100) >>> rel_pos = tiprack[0].from_center(x=0, y=0, z=-1, reference=tiprack) >>> p200.calibrate_position((tiprack, rel_pos)) <opentrons.instruments.pipette.Pipette object at ...>
- location (tuple(
-
delay(seconds=0, minutes=0)¶ Parameters: seconds (float) – The number of seconds to freeeze in place.
-
dispense(volume=None, location=None, rate=1.0)¶ Dispense a volume of liquid (in microliters/uL) using this pipette
Notes
If no location is passed, the pipette will dispense from it’s current position. If no volume is passed, dispense will default to it’s current_volume
Parameters: - volume (int or float) – The number of microliters to dispense (Default: self.current_volume)
- location (
Placeableor tuple(Placeable,Vector)) – ThePlaceable(Well) to perform the dispense. Can also be a tuple with first itemPlaceable, second item relativeVector - rate (float) – Set plunger speed for this dispense, where
speed = rate * dispense_speed (see
set_speed())
Returns: Return type: This instance of
Pipette.Examples
>>> p200 = instruments.Pipette(name='p200', axis='a', max_volume=200) >>> # fill the pipette with liquid (200uL) >>> p200.aspirate(plate[0]) <opentrons.instruments.pipette.Pipette object at ...>
>>> # dispense 50uL to a Well >>> p200.dispense(50, plate[0]) <opentrons.instruments.pipette.Pipette object at ...>
>>> # dispense 50uL to the center of a well >>> relative_vector = plate[1].center() >>> p200.dispense(50, (plate[1], relative_vector)) <opentrons.instruments.pipette.Pipette object at ...>
>>> # dispense 20uL in place, at half the speed >>> p200.dispense(20, rate=0.5) <opentrons.instruments.pipette.Pipette object at ...>
>>> # dispense the pipette's remaining volume (80uL) to a Well >>> p200.dispense(plate[2]) <opentrons.instruments.pipette.Pipette object at ...>
-
drop_tip(location=None, home_after=True)¶ Drop the pipette’s current tip
Notes
If no location is passed, the pipette defaults to its trash_container (see
Pipette)Parameters: location ( Placeableor tuple(Placeable,Vector)) – ThePlaceable(Well) to perform the drop_tip. Can also be a tuple with first itemPlaceable, second item relativeVectorReturns: Return type: This instance of Pipette.Examples
>>> robot.reset() <opentrons.robot.robot.Robot object at ...> >>> tiprack = containers.load('tiprack-200ul', 'A1') >>> trash = containers.load('point', 'A1') >>> p200 = instruments.Pipette(axis='a', trash_container=trash) >>> p200.pick_up_tip(tiprack[0]) <opentrons.instruments.pipette.Pipette object at ...> >>> # drops the tip in the trash >>> p200.drop_tip() <opentrons.instruments.pipette.Pipette object at ...> >>> p200.pick_up_tip(tiprack[1]) <opentrons.instruments.pipette.Pipette object at ...> >>> # drops the tip back at its tip rack >>> p200.drop_tip(tiprack[1]) <opentrons.instruments.pipette.Pipette object at ...>
-
home()¶ Home the pipette’s plunger axis during a protocol run
Notes
Pipette.home() homes the Robot
Returns: Return type: This instance of Pipette.Examples
>>> p200 = instruments.Pipette(axis='a') >>> p200.home() <opentrons.instruments.pipette.Pipette object at ...>
-
mix(repetitions=1, volume=None, location=None, rate=1.0)¶ Mix a volume of liquid (in microliters/uL) using this pipette
Notes
If no location is passed, the pipette will mix from it’s current position. If no volume is passed, mix will default to it’s max_volume
Parameters: - repetitions (int) – How many times the pipette should mix (Default: 1)
- volume (int or float) – The number of microliters to mix (Default: self.max_volume)
- location (
Placeableor tuple(Placeable,Vector)) – ThePlaceable(Well) to perform the mix. Can also be a tuple with first itemPlaceable, second item relativeVector - rate (float) – Set plunger speed for this mix, where
speed = rate * (aspirate_speed or dispense_speed)
(see
set_speed())
Returns: Return type: This instance of
Pipette.Examples
>>> p200 = instruments.Pipette(name='p200', axis='a', max_volume=200)
>>> # mix 50uL in a Well, three times >>> p200.mix(3, 50, plate[0]) <opentrons.instruments.pipette.Pipette object at ...>
>>> # mix 3x with the pipette's max volume, from current position >>> p200.mix(3) <opentrons.instruments.pipette.Pipette object at ...>
-
move_to(location, strategy='arc')¶ Move this
Pipetteto aPlaceableon theDeckNotes
Until obstacle-avoidance algorithms are in place,
RobotandPipettemove_to()use either an “arc” or “direct”Parameters: - location (
Placeableor tuple(Placeable,Vector)) – The destination to arrive at - strategy ("arc" or "direct") – “arc” strategies (default) will pick the head up on Z axis, then over to the XY destination, then finally down to the Z destination. “direct” strategies will simply move in a straight line from the current position
Returns: Return type: This instance of
Pipette.- location (
-
pick_up_tip(location=None, presses=3)¶ Pick up a tip for the Pipette to run liquid-handling commands with
Notes
A tip can be manually set by passing a location. If no location is passed, the Pipette will pick up the next available tip in it’s tip_racks list (see
Pipette)Parameters: location ( Placeableor tuple(Placeable,Vector)) – ThePlaceable(Well) to perform the pick_up_tip. Can also be a tuple with first itemPlaceable, second item relativeVectorReturns: Return type: This instance of Pipette.Examples
>>> robot.reset() <opentrons.robot.robot.Robot object at ...> >>> tiprack = containers.load('tiprack-200ul', 'A1') >>> p200 = instruments.Pipette(axis='a', tip_racks=[tiprack]) >>> p200.pick_up_tip(tiprack[0]) <opentrons.instruments.pipette.Pipette object at ...> >>> p200.return_tip() <opentrons.instruments.pipette.Pipette object at ...> >>> # `pick_up_tip` will automatically go to tiprack[1] >>> p200.pick_up_tip() <opentrons.instruments.pipette.Pipette object at ...> >>> p200.return_tip() <opentrons.instruments.pipette.Pipette object at ...>
-
return_tip(home_after=True)¶ Drop the pipette’s current tip to it’s originating tip rack
Notes
This method requires one or more tip-rack
Containerto be in this Pipette’s tip_racks list (seePipette)Returns: Return type: This instance of Pipette.Examples
>>> tiprack = containers.load('tiprack-200ul', 'A1') >>> p200 = instruments.Pipette(axis='a', ... tip_racks=[tiprack], max_volume=200, name='p200') >>> p200.pick_up_tip() <opentrons.instruments.pipette.Pipette object at ...> >>> p200.aspirate(50, plate[0]) <opentrons.instruments.pipette.Pipette object at ...> >>> p200.dispense(plate[1]) <opentrons.instruments.pipette.Pipette object at ...> >>> p200.return_tip() <opentrons.instruments.pipette.Pipette object at ...>
-
set_speed(**kwargs)¶ Set the speed (mm/minute) the
Pipetteplunger will move duringaspirate()anddispense()Parameters: kwargs (Dict) – A dictionary who’s keys are either “aspirate” or “dispense”, and who’s values are int or float (Example: {“aspirate”: 300})
-
touch_tip(location=None, radius=1.0)¶ Touch the
Pipettetip to the sides of a well, with the intent of removing left-over dropletsNotes
If no location is passed, the pipette will touch_tip from it’s current position.
Parameters: - location (
Placeableor tuple(Placeable,Vector)) – ThePlaceable(Well) to perform the touch_tip. Can also be a tuple with first itemPlaceable, second item relativeVector - radius (float) – Radius is a floating point number between 0.0 and 1.0, describing
the percentage of a well’s radius. When radius=1.0,
touch_tip()will move to 100% of the wells radius. When radius=0.5,touch_tip()will move to 50% of the wells radius.
Returns: Return type: This instance of
Pipette.Examples
>>> p200 = instruments.Pipette(name='p200', axis='a', max_volume=200) >>> p200.aspirate(50, plate[0]) <opentrons.instruments.pipette.Pipette object at ...> >>> p200.dispense(plate[1]).touch_tip() <opentrons.instruments.pipette.Pipette object at ...>
- location (