Versioning

The Python Protocol API has its own versioning system, which is separate from the versioning system used for the robot software and the Opentrons App. This allows protocols to run on newer robot software versions without modification.

Major and minor versions

The API uses a major and minor version number and does not use patch version numbers. For instance, major version 2 and minor version 0 is written as 2.0. Versions are not decimal numbers, so 2.10 indicates major version 2 and minor version 10. The Python Protocol API version will only increase based on changes that affect protocol behavior.

The major version of the API increases whenever there are significant structural or behavioral changes to protocols. For instance, major version 2 of the API was introduced because it required protocols to have a run function that takes a protocol argument rather than importing the robot, instruments, and labware modules. Protocols written with major version 1 of the API will not run without modification in major version 2. A similar level of structural change would require a major version 3. This documentation only deals with features found in major version 2 of the API; see the archived version 1 documentation for information on older protocols.

The minor version of the API increases whenever there is new functionality that might change the way a protocol is written, or when a behavior changes in one aspect of the API but does not affect all protocols. For instance, adding support for a new hardware module, adding new parameters for a function, or deprecating a feature would increase the minor version of the API.

Specifying versions

You must specify the API version you are targeting in your Python protocol. In all minor versions, you can do this with the apiLevel key in the metadata dictionary, alongside any other metadata elements:

from opentrons import protocol_api

metadata = {
    "apiLevel": "2.27",
    "author": "A. Biologist"
}

def run(protocol: protocol_api.ProtocolContext):
    protocol.comment("Hello, world!")

From version 2.15 onward, you can specify apiLevel in the requirements dictionary instead:

from opentrons import protocol_api

metadata = {"author": "A. Biologist"}
requirements = {"apiLevel": "2.27", "robotType": "Flex"}

def run(protocol: protocol_api.ProtocolContext):
    protocol.comment("Hello, Flex!")

Choose only one of these places to specify apiLevel. If you put it in neither or both places, you will not be able to simulate or run your protocol.

The version you specify determines the features and behaviors available to your protocol. For example, support for the Heater-Shaker Module was added in version 2.13, so you can't specify a lower version and then call HeaterShakerContext methods without causing an error. This protects you from accidentally using features not present in your specified API version, and keeps your protocol portable between API versions.

When choosing an API level, consider what features you need and how widely you plan to share your protocol. Throughout the Python Protocol API documentation, there are version statements indicating when elements (features, function calls, available properties, etc.) were introduced. Keep these in mind when specifying your protocol's API version. Version statements look like this:

New in version 2.0

On the one hand, using the highest available version will give your protocol access to all the latest features and fixes. On the other hand, using the lowest possible version lets the protocol work on a wider range of robot software versions. For example, a protocol that uses the Heater-Shaker and specifies version 2.13 of the API should work equally well on a robot running version 6.1.0 or 6.2.0 of the robot software. Specifying version 2.14 would limit the protocol to robots running 6.2.0 or higher.

Maximum supported versions

The maximum supported API version for your robot is listed in the Opentrons App under Robots > your robot > Robot Settings > Advanced. Before version 6.0.0 of the app, the same information was listed on your robot's Information card.

If you upload a protocol that specifies a higher API level than the maximum supported, your robot won't be able to analyze or run your protocol. You can increase the maximum supported version by updating your robot software and Opentrons App.

Opentrons robots running the latest software (8.8.0) support the following version ranges:

  • Flex: version 2.15–2.27.
  • OT-2: versions 2.0–2.27.

API and robot software versions

This table lists the correspondence between Protocol API versions and robot software versions.

API Version Introduced in Robot Software
2.28 9.0.0
2.27 8.8.0
2.26 8.7.0
2.25 8.6.0
2.24 8.5.0
2.23 8.4.0
2.22 8.3.0
2.21 8.2.0
2.20 8.0.0
2.19 7.3.1
2.18 7.3.0
2.17 7.2.0
2.16 7.1.0
2.15 7.0.0
2.14 6.3.0
2.13 6.1.0
2.12 5.0.0
2.11 4.4.0
2.10 4.3.0
2.9 4.1.0
2.8 4.0.0
2.7 3.21.0
2.6 3.20.0
2.5 3.19.0
2.4 3.17.1
2.3 3.17.0
2.2 3.16.0
2.1 3.15.2
2.0 3.14.0
1.0 3.0.0

Changes in API versions

Version 2.28

  • Return tips to the tip rack with a pipette that's configured to use partial tip pickup.
  • Adds additional tools to customize pipette blowouts:
    • an absolute flow_rate.
    • a blowout position for a liquid class transfer.
  • Simplifies customizing liquid class tip positions, including aspirate, dispense, and blowout positions.
  • Control how quickly the Thermocycler Module's block heats or cools with the set_block_temperature() and start_set_block_temperature() methods' optional ramp_rate parameter.
  • Use the drop_tip() method's optional alternate_drop_location argument to vary the tip drop location in a waste container, preventing tips from piling up in a single location.
  • In protocols using API version 2.28, the API raises an error when calling touch_tip() in large spaces, like reservoirs and large well plates.

Version 2.27

Version 2.26

  • Adds the ability to use the flex_96channel_200 pipette to perform liquid handling actions using liquid classes.

Version 2.25

  • Adds FlexStackerContext to support the Flex Stacker Module. Use the load name flexStackerModuleV1 with ProtocolContext.load_module() to add a Flex Stacker and automate labware storage in a protocol.
  • Use the load name flex_96channel_200 with load_instrument() to add the Opentrons Flex 96-Channel Pipette (1–200 μL) to a protocol. Note that this pipette does not work with liquid class commands in this API version.

Version 2.24

  • Adds the ability to perform liquid handling actions using liquid classes.
  • ProtocolContext.get_liquid_class accesses Opentrons-verified liquid class definitions for aqueous, volatile, and viscous liquids.
  • ProtocolContext.define_liquid_class lets you create your own liquid classes from verified classes or from scratch.
  • New InstrumentContext methods — transfer_with_liquid_class, distribute_with_liquid_class, and consolidate_with_liquid_class — move liquids according to their properties.
  • air_gap, blow_out, dispense, mix, and touch_tip have new parameters for advanced settings that are also available in Protocol Designer.

Version 2.23

  • Wells now have a meniscus() location that corresponds to the top of the liquid, either as set in the protocol or measured by probing with a pipette tip. See Meniscus.
  • Load and move labware lids with a new lid parameter of ProtocolContext.load_labware() and standalone methods. See Loading Lids and Moving Lids.
  • Updated set_offset() to match new Labware Position Check behavior in Opentrons App v8.4.0.

Version 2.22

  • Improvements to loading liquids. Use the new Labware.load_liquid, Labware.load_liquid_by_well, and Labware.load_empty methods instead of Well.load_liquid(), which is now deprecated.
  • Use new robot motor control methods to control individual robot motors.
    • The RobotContext.move_to(), RobotContext.move_axes_to(), and RobotContext.move_axes_relative() methods move robot motors to specific deck positions.
    • Calculate specific deck positions with the RobotContext.axis_coordinates_for() method, and pipette plunger positions with RobotContext.plunger_coordinates_for_volume() and RobotContext.plunger_coordinates_for_named_position().
    • Control the Flex Gripper with the RobotContext.open_gripper_jaw() and RobotContext.close_gripper_jaw() methods.
  • Beta features for our commercial partners.

Version 2.21

Version 2.20

  • Detect liquid presence within a well. The InstrumentContext.detect_liquid_presence() and InstrumentContext.require_liquid_presence() building block commands check for liquid any point in your protocol. You can also enable liquid presence detection for all aspirations when loading a pipette, although this will add significant time to your protocol.
  • Define CSV runtime parameters and use their contents in a protocol with new data manipulation methods. See the cherrypicking use case for a full example.
  • configure_nozzle_layout() now accepts row, single, and partial column layout constants. See Partial Tip Pickup.
  • You can now call ProtocolContext.define_liquid() without supplying a description or display_color.

Version 2.19

Opentrons recommends updating protocols from apiLevel 2.18 to 2.19 to take advantage of improved pipetting behavior.

This version uses new values for how much a tip overlaps with the pipette nozzle when the pipette picks up tips. This can correct errors caused by the robot positioning the tip slightly lower than intended, potentially making contact with labware. See pick_up_tip() for additional details.

Version 2.18

  • Define customizable parameters with the new add_parameters() function, and access their values on the ProtocolContext.params object during a protocol run. See Runtime Parameters and related pages for more information.
  • Move the pipette to positions relative to the top of a trash container. See Position Relative to Trash Containers. The default behavior of drop_tip also accounts for this new possibility.
  • set_offset() has been restored to the API with new behavior that applies to labware type–location pairs.
  • Automatic tip tracking is now available for all nozzle configurations.

Version 2.17

dispense() now raises an error if you try to dispense more than InstrumentContext.current_volume.

Version 2.16

This version introduces new features for Flex and adds and improves methods for aspirating and dispensing. Note that when updating Flex protocols to version 2.16, you must load a trash container before dropping tips.

  • New features
    • Use configure_nozzle_layout() to pick up a single column of tips with the 96-channel pipette. See Partial Tip Pickup.
    • Specify the trash containers attached to your Flex with load_waste_chute() and load_trash_bin().
    • Dispense, blow out, drop tips, and dispose labware in the waste chute. Disposing labware requires the gripper and calling move_labware() with use_gripper=True.
    • Perform actions in staging area slots by referencing slots A4 through D4. See Deck Slots.
    • Explicitly command a pipette to prepare_to_aspirate(). The API usually prepares pipettes to aspirate automatically, but this is useful for certain applications, like pre-wetting routines.
  • Improved features
    • aspirate(), dispense(), and mix() will not move any liquid when called with volume=0.
  • Other changes
    • ProtocolContext.fixed_trash and InstrumentContext.trash_container now return TrashBin objects instead of Labware objects.
    • Flex will no longer automatically drop tips in the trash at the end of a protocol. You can add a drop_tip() command to your protocol or use the Opentrons App to drop the tips.

Version 2.15

This version introduces support for the Opentrons Flex robot, instruments, modules, and labware.

  • Flex features
    • Write protocols for Opentrons Flex by declaring "robotType": "Flex" in the new requirements dictionary. See the examples in the Tutorial.
    • load_instrument() supports loading Flex 1-, 8-, and 96-channel pipettes. See Loading Pipettes.
    • The new move_labware() method can move labware automatically using the Flex Gripper. You can also move labware manually on Flex.
    • load_module() supports loading the Magnetic Block.
    • The API does not enforce placement restrictions for the Heater-Shaker module on Flex, because it is installed below-deck in a module caddy. Pipetting restrictions are still in place when the Heater-Shaker is shaking or its labware latch is open.
    • The new configure_for_volume() method can place Flex 50 µL pipettes in a low-volume mode for dispensing very small volumes of liquid. See Volume Modes.
  • Flex and OT-2 features
    • Optionally specify apiLevel in the new requirements dictionary (otherwise, specify it in metadata).
    • Optionally specify "robotType": "OT-2" in requirements.
    • Use coordinates or numbers to specify deck slots. These formats match physical labels on Flex and OT-2, but you can use either system, regardless of robotType.
    • The new module context load_adapter() methods let you load adapters and labware separately on modules, and ProtocolContext.load_adapter() lets you load adapters directly in deck slots. See Loading Labware on Adapters.
    • Move labware manually using move_labware(), without having to stop your protocol.
    • Manual labware moves support moving to or from the new OFF_DECK location (outside of the robot).
    • ProtocolContext.load_labware() also accepts OFF_DECK as a location. This lets you prepare labware to be moved onto the deck later in a protocol.
    • The new push_out parameter of the dispense() method helps ensure that the pipette dispenses all of its liquid when working with very small volumes.
    • By default, repeated calls to drop_tip() cycle through multiple locations above the trash bin to prevent tips from stacking up.
  • Bug fixes
    • InstrumentContext.starting_tip is now respected on the second and subsequent calls to InstrumentContext.pick_up_tip() with no argument.

Version 2.14

This version introduces a new protocol runtime that offers more reliable run control and builds a strong foundation for future Protocol API improvements.

Several older parts of the Protocol API were deprecated as part of this switchover. If you specify an API version of 2.13 or lower, your protocols will continue to execute on the old runtime.

  • Feature additions
    • ProtocolContext.define_liquid() and Well.load_liquid() added to define different liquid types and add them to wells, respectively.
  • Bug fixes
    • Labware and Well now adhere to the protocol's API level setting. Prior to this version, they incorrectly ignored the setting.
    • InstrumentContext.touch_tip() will end with the pipette tip in the center of the well instead of on the edge closest to the front of the machine.
    • ProtocolContext.load_labware() now prefers loading user-provided labware definitions rather than built-in definitions if no explicit namespace is specified.
    • ProtocolContext.pause() will now properly wait until you resume the protocol before moving on. In previous versions, the run will not pause until the first call to a different ProtocolContext method.
    • Motion planning has been improved to avoid certain erroneous downward movements, especially when using InstrumentContext.aspirate().
    • Labware.reset() and Labware.tip_length will raise useful errors if called on labware that is not a tip rack.
  • Removals
    • The presses and increment arguments of InstrumentContext.pick_up_tip() were deprecated. Configure your pipette pick-up settings with the Opentrons App, instead.
    • InstrumentContext.speed property was removed. This property tried to allow setting a pipette's plunger speed in mm/s. However, it could only approximately set the plunger speed, because the plunger's speed is a stepwise function of the volume. Use InstrumentContext.flow_rate to set the flow rate in µL/s, instead.
    • load_labware_object() was removed from module contexts as an unnecessary internal method.
    • geometry was removed from module contexts in favor of model and type attributes.
    • Well.geometry was removed as unnecessary.
    • MagneticModuleContext.calibrate was removed since it was never needed nor implemented.
    • The height parameter of MagneticModuleContext.engage() was removed. Use offset or height_from_base instead.
    • Labware.separate_calibration and Labware.set_calibration() were removed, since they were holdovers from a calibration system that no longer exists.
    • Various methods and setters were removed that could modify tip state outside of calls to InstrumentContext.pick_up_tip and InstrumentContext.drop_tip(). This change allows the robot to track tip usage more completely and reliably. You may still use Labware.reset() and InstrumentContext.reset_tipracks() to reset your tip racks' state.
      • The Well.has_tip setter was removed. The getter is still supported.
      • Internal methods Labware.use_tips(), Labware.previous_tip(), and Labware.return_tips() were removed.
    • The configuration argument of ProtocolContext.load_module() was removed because it made unsafe modifications to the protocol's geometry system, and the Thermocycler's "semi" configuration is not officially supported.
  • Known limitations
    • Labware.set_offset() is not yet supported on this API version. Run protocols via the Opentrons App, instead.
    • ProtocolContext.max_speeds is not yet supported on the API version. Use InstrumentContext.default_speed or the per-method speed argument, instead.
    • InstrumentContext.starting_tip is not respected on the second and subsequent calls to InstrumentContext.pick_up_tip() with no argument.

Version 2.13

  • Adds HeaterShakerContext to support the Heater-Shaker Module. You can use the load name heaterShakerModuleV1 with ProtocolContext.load_module to add a Heater-Shaker to a protocol.
  • InstrumentContext.drop_tip() now has a prep_after parameter.
  • InstrumentContext.home() may home both pipettes as needed to avoid collision risks.
  • InstrumentContext.aspirate() and InstrumentContext.dispense() will avoid interacting directly with modules.

Version 2.12

  • ProtocolContext.resume() has been deprecated.
  • Labware.set_offset() has been added to apply labware offsets to protocols run (exclusively) outside of the Opentrons App (Jupyter Notebook and SSH).

Version 2.11

  • Attempting to aspirate from or dispense to tip racks will raise an error.

Version 2.10

  • Moving to the same well twice in a row with different pipettes no longer results in strange diagonal movements.

Version 2.9

  • You can now access certain geometry data regarding a labware's well via a Well object. See Well Dimensions for more information.

Version 2.8

  • You can now pass in a list of volumes to distribute and consolidate. See List of Volumes for more information.
    • Passing in a zero volume to any complex command will result in no actions taken for aspirate or dispense.
  • Well.from_center_cartesian() can be used to find a point within a well using normalized distance from the center in each axis.
    • Note that you will need to create a location object to use this function in a protocol. See Labware for more information.
  • You can now pass in a blowout location to transfer, distribute, and consolidate with the blowout_location parameter. See InstrumentContext.transfer() for more detail!

Version 2.7

  • Added InstrumentContext.pair_with(), an experimental feature for moving both pipettes simultaneously.

    Note

    This feature has been removed from the Python Protocol API.

  • Calling InstrumentContext.has_tip() will return whether a particular instrument has a tip attached or not.

Version 2.6

  • GEN2 Single pipettes now default to flow rates equivalent to 10 mm/s plunger speeds
    • Protocols that manually configure pipette flow rates will be unaffected
    • For a comparison between API Versions, see OT-2 Pipette Flow Rates

Version 2.5

  • New utility commands were added:
    • ProtocolContext.set_rail_lights(): turns robot rail lights on or off
    • ProtocolContext.rail_lights_on: describes whether or not the rail lights are on
    • ProtocolContext.door_closed: describes whether the robot door is closed

Version 2.4

  • The following improvements were made to the touch_tip command:
    • The speed for touch_tip can now be lowered down to 1 mm/s
    • touch_tip no longer moves diagonally from the X direction -> Y direction
    • Takes into account geometry of the deck and modules

Version 2.3

  • Magnetic Module GEN2 and Temperature Module GEN2 are now supported; you can load them with the names "magnetic module gen2" and "temperature module gen2", respectively.
  • All pipettes will return tips to tip racks from a higher position to avoid possible collisions.
  • During a mix(), the pipette will no longer move up to clear the liquid in between every dispense and following aspirate.
  • You can now access the Temperature Module's status via TemperatureModuleContext.status.

Version 2.2

  • You should now specify Magnetic Module engage height using the height_from_base parameter, which specifies the height of the top of the magnet from the base of the labware. For more, see Engaging and Disengaging.
  • Return tip will now use pre-defined heights from hardware testing. For more information, see Returning a Tip.
  • When using the return tip function, tips are no longer added back into the tip tracker. For more information, see Returning a Tip.

Version 2.1

  • When loading labware onto a module, you can now specify a label with the label parameter of MagneticModuleContext.load_labware(), TemperatureModuleContext.load_labware(), or ThermocyclerContext.load_labware(), just like you can when loading labware onto the deck with ProtocolContext.load_labware().

Version 2.0

Version 2 of the API is a new way to write Python protocols, with support for new modules like the Thermocycler. To transition your protocols from version 1 to version 2 of the API, follow this migration guide.

We've also published a more in-depth discussion of why we developed version 2 of the API and how it differs from version 1.