System Specifications
General specifications¶
| Specification | Details | 
|---|---|
| Dimensions | 87 × 69 × 84 cm / 34.25 × 27 × 33 in (W, D, H) | 
| Weight | 88.5 kg / 195 lb | 
| Deck slots | 
 | 
| Touchscreen | 7-inch LCD touchscreen with scratch-resistant and damage-resistant Gorilla Glass 3 | 
| Wi-Fi | 802.11 ac/a/b/g/n dual-band (2.4/5 GHz) | 
| Ethernet | 100 Mbps | 
| USB | 
 | 
| Camera | 2MP, photo and video | 
| Robot power input | 
 | 
| Mains supply voltage fluctuation | ±10% | 
| Mains supply frequency fluctuation | ±5% | 
| Distribution system | TN-S | 
| Short-circuit supply current | 6.3 A | 
| Frame composition | Rigid steel and CNC aluminum design | 
| Window composition | Removable polycarbonate side windows and front door | 
| Ventilation requirements | At least 20 cm / 8 in between the unit and a wall | 
| Connected PC requirements | The Opentrons App runs on: 
 | 
Environmental specifications¶
| Specification | Details | 
|---|---|
| Environmental conditions | Indoor use only | 
| Ambient temperature | +20 to +25 °C (recommended) | 
| Relative humidity | 40–60%, non-condensing (recommended) | 
| Pollution degree | 2 (non-conductive pollution only) | 
For additional information on acceptable environmental conditions for use and transport, see the Environmental Conditions section of the Installation and Relocation chapter.
Certifications¶
| Certification | Status | 
|---|---|
| Certifications complete | CE, ETL, FCC, ISO 9001 | 
| Not certified/validated | IVD, GMP | 
A summary of certification information is printed on a sticker on the back of Flex, near the on/off switch. For detailed certification and compliance information, see the Regulatory Compliance section.
Serial number¶
Every Flex has a unique serial number. The format of the serial number
provides additional information, including the robot's date of
production. For example, the serial number FLXA1020231007001 would
indicate:
| Characters | Category | Meaning | 
|---|---|---|
| FLX | Model | The robot is an Opentrons Flex. | 
| A10 | Version | A code for the production version of the robot. | 
| 2023 | Year | The robot was made in 2023. | 
| 10 | Month | The robot was made in October. | 
| 07 | Day | The robot was made on the 7th day of the month. | 
| 001 | Unit | A unique number for robots made on a certain day. | 
You can find the serial number for your Flex:
- 
On the certification sticker on the back of Flex, near the on/off switch. 
- 
On the reverse side of the touchscreen (towards the working area). 
- 
In the Opentrons App under Devices > your Flex > Robot settings > Advanced.